MAX6310UK35D2-T belongs to the category of integrated circuits (ICs).
This IC is commonly used for voltage monitoring and reset functions in various electronic devices.
MAX6310UK35D2-T is available in a small outline transistor (SOT) package, specifically SOT23-5.
The essence of MAX6310UK35D2-T lies in its ability to monitor voltage levels and provide reset signals to ensure proper functioning of electronic systems.
This IC is typically packaged in reels or tubes, with a quantity of 3000 units per reel/tube.
MAX6310UK35D2-T has a total of five pins arranged as follows:
```
| | --|----|-- VCC --|----|-- GND --|----|-- RESET --|----|-- MR |____| ```
MAX6310UK35D2-T operates by comparing the supply voltage with the preset threshold value. When the voltage drops below the threshold, the internal circuitry triggers a reset signal. This signal remains active until the voltage rises above the threshold or a manual reset is initiated through the MR pin.
MAX6310UK35D2-T finds application in various electronic systems that require reliable voltage monitoring and reset functionality. Some potential application fields include:
These alternative models provide flexibility in selecting the appropriate IC based on specific voltage requirements and timing constraints.
Word count: 570 words
Sure! Here are 10 common questions and answers related to the application of MAX6310UK35D2-T in technical solutions:
Q: What is the MAX6310UK35D2-T? A: The MAX6310UK35D2-T is a voltage monitor and reset circuit that provides power supply monitoring and reset generation for microcontrollers, DSPs, and other digital systems.
Q: What is the operating voltage range of MAX6310UK35D2-T? A: The operating voltage range of MAX6310UK35D2-T is from 1.6V to 5.5V.
Q: How does MAX6310UK35D2-T monitor the power supply? A: MAX6310UK35D2-T monitors the power supply by comparing the monitored voltage with a preset threshold voltage. If the monitored voltage falls below the threshold, it generates a reset signal.
Q: Can I adjust the threshold voltage of MAX6310UK35D2-T? A: No, the threshold voltage of MAX6310UK35D2-T is fixed at 3.5V.
Q: What is the typical reset time delay of MAX6310UK35D2-T? A: The typical reset time delay of MAX6310UK35D2-T is 140ms.
Q: Does MAX6310UK35D2-T have an open-drain output? A: Yes, MAX6310UK35D2-T has an open-drain reset output.
Q: Can I use MAX6310UK35D2-T in battery-powered applications? A: Yes, MAX6310UK35D2-T can be used in battery-powered applications as it operates within a wide voltage range and has low quiescent current.
Q: What is the maximum supply current of MAX6310UK35D2-T? A: The maximum supply current of MAX6310UK35D2-T is 10µA.
Q: Is MAX6310UK35D2-T available in different package options? A: Yes, MAX6310UK35D2-T is available in a SOT23-3 package.
Q: Can I use MAX6310UK35D2-T in automotive applications? A: No, MAX6310UK35D2-T is not specifically designed for automotive applications and may not meet the required standards.